NDT INSTRUMENTS
ULTRASONIC THICKNESS GAUGE PG-H001
Introduction
Ultrasonic Thickness Gauge measuring with ultrasonic wave is applicable for measuring the thickness of any material in which ultrasonic wave can be transmitted and reflected back from the other face. The gauge can provide quick and accurate measurement to various work pieces such as sheets of board and processing parts. Another important application of the gauge is to monitor various pipes and pressure vessels in production equipment, and monitor the thinning degree during using. It can be widely used in petroleum, chemical, metallurgy, shipping, aerospace, aviation and other fields.
1.1 Technical Specification
- Display:128*64 LCD with LED backlight;
- Measuring Range:(0.75~600)mm(Steel)
- Velocity Range:(1000~9999) m/s;
- Resolution:0.001mm
- Measuring accuracy: ±(0.5%H+0.04mm);H is thickness value
- Measurement cycle:Single point measurement 6 times/per
- Storage:3000 values of saved data
- Communication Port:RS232
- Power Source:2pcs 1.5V AA size
- Working Time:more than 50 hours (LED backlight off).
- Outline Dimensions:150mm*74mm*32 mm
- Weight:238g
Other Size and Type Available on Request.
PG-10 High-Precision ULTRASONIC Thickness Gauge
Ultrasonic Thickness Gauges are designed to improve safety and ensure reliability of material subject to corrosion or erosion.
Corrosion gauges with their dual-element transducers are the primary inspection tool used to measure the remaining walls of components such as pipelines, pressure vessels, storage tanks, and numerous other applications..
Precision gauges use single-element transducers to provide the thinnest range and highest degree of accuracy possible. Common applications include metals and a variety of non-metals (i.e. glass, ceramic, plastic, etc.)
Specifications:
Measuring Range | 0.65 mm – 400mm (upto 500mm) (in steel) |
Sound Velocity | 1000~9999 m/s |
Resolution | 0.01mm/0.1mm or 0.001/0.01” selectable |
Units | mm/inch (selectable) |
Memory | Upto 2000 Groups (up to 99 Values for each file) |
Accuracy | ± ( 0.5%Thickness+0.04 ) mm |
Alarm | preset upper and lower limit |
Work voltage | 3V( 2 AA alkaline battaries) |
Work mode | Single point and scan |
Interface port | USB |
Dimensions | 136 x 72 x 20mm |
Weight | 177 g |
Display | 3.5 digit LCD with EL backlight |
Continuous working period | 280 hours (with EL backlight off) |
Standard Delivery: Main Unit,, TWO test Probes, Data Cable, Software, Coupling oil, Battery, Operation Manual, Carrying case.
PG-ABD Ultrasonic Thickness Gauge A&B Scan Thru-Paint&Coatings Thickness Gauge
Product Description:
PG-AB Series Color Screen with A/B-Scan Ultrasonic Thickness Gauge Professional in Solving Various Difficult Thickness Measurement
Features:
2.4” color OLED, 320 X 240 pixels, contrast 10,000:1
Live Color A-Scan
Users could directly see the color waveform of the ultrasonic sound (or A-scan) on the screen, which is quite important for the occasions that we need to check the correctness of the testing results. Many cases will cause wrong testing results or even no readings. We could find the causes easily through the A-scan. Adjust the three parameters of GAIN, BLACKING, GATE, and then we will get the right readings.
Live Color B-Scan
PG-AB series thickness gauge has time base B-scan function. Move the probe along the workpiece surface, then the cross -sectional profile of the workpiece display, use for observe the underside contour of the workpiece.It could be automatically capture a minimum value of the B-scan image, and indicate the position of the minimum by a red triangle. You can see any point thickness value of the B-scan image by moving the pointer.
Through Coating Function No longer need to waste time to remove the coating
Now PG-ABD and PG-ABDL also have this widely acclaimed function. It’s realized by measuring the two continuous bottom surface of the substrate. This mode also has more advantages:
- Exempt Zero Calibration
- High Stability, the measuring value is not influenced by the probe pressure, the coupling layer thickness and the surface dust of the workpiece.
- Zero Drift
Other Size and Type Available on Request.
More Practical Function :
Difference/Reduction Rate: Difference mode displays the difference between the actual value and the normal value. Reduction rate calculates and shows the percentage of the thickness reduction when the material becomes thin. Typical application is to measure the metal material which is due to bending and becomes thin.
Max./Min. Capture: On this mode, the current thickness, minimum thickness and the maximum thickness will be shown on the screen at the same time.
Alarm Mode: Dynamic change the color of thickness readings when alarming.
Update Rate: Selectable 4Hz, 8hz and 16Hz. 4Hz for ordinary application, when you need a quick scan, such as high temperature measurement, you can choose higher update frequency.
Multi- Languages Available: Chinese, English, Japanese, French, German.
Standard PG510 Probe:
The probe is the heart of the instrument. PG510 probe uses the high performance piezoelectric ceramic chip, with integrated metal die-casting shell, practical design of probe and cable separated, regardless of costs to create high quality .
The Difference Between PG-AB Series Ultrasonic Thickness Gauge
| PG-AB | PG-ABD | PG-ABDL |
Color Display | √ | √ | √ |
Live A-Scan | √ | √ | √ |
Time-based B-Scan | √ | √ | √ |
Control of Gain and Gate | √ | √ | √ |
Blanking | √ | √ | √ |
Thru-paint&coatings | × | √ | √ |
Data Logger | × | × | √ |
DataView Software | × | × | √ |
Specifications Of PG-ABDL Ultrasonic Thickness Gauge
Display Type | 2.4” color OLED, 320×240 pixels, contrast 10,000:1 |
Operating Principle | Pulse echo with dual elemet transducers |
Measuring Range | 0.50mm to 508mm(0.02” to 20.00”), depending on material, probe and surface condition |
Measuring Resolution | Selectable 0.01mm, 0.1mm(selectable 0.001”, 0.01”) |
Units | Inch or Millimeter |
Rectify Mode | RF+, RF-, HALF+, HALF-, FULL |
Display Mode | Normal, Minimum/Maximum capture, DIFF/RR%, A-Scan, B-Scan |
V-Path Correction | Automatic |
Update Rate | Selectable 4Hz, 8Hz, 16Hz |
Material Velocity Range | 500 to 9999m/s(0.0197 to 0.3939 in/μs) |
Languages | English, French, German, Japanese,Chinese |
Alarm Settings | Minimum and Maximum alarms. Range of 0.25mm to 508mm (0.010” to 20.00”). Dynamic waveform color change on alarm |
Power Requirements | 2 AA size batteries |
Operating Time | Approximately 40 hours |
Instrument Shut-off | Selectable ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity |
Operating Temperature | -10℃ to +50℃(+10°F to +12°F ) |
Size | 156mm × 75mm × 38mm (H × W × D) |
Weight | 270g including batteries |
Other Size and Type Available on Request.
Detailed Information
Display Type: | 2.4” Color OLED, 320×240 Pixels, Contrast 10,000:1 | Operating Principle: | Pulse Echo With Dual Elemet Transducers |
Measuring Range: | 0.50mm To 508mm(0.02” To 20.00”), Depending On Material, Probe And Surface Condition | Measuring Resolution: | Selectable 0.01mm, 0.1mm(selectable 0.001”, 0.01”) |
Units: | Inch Or Millimeter | Rectify Mode: | RF+, RF-, HALF+, HALF-, FULL |
Display Mode: | Normal, Minimum/Maximum Capture, DIFF/RR%, A-Scan, B-Scan | V-Path Correction: | Automatic |
Update Rate: | Selectable 4Hz, 8Hz, 16Hz | Material Velocity Range: | 500 To 9999m/s(0.0197 To 0.3939 In/μs) |
High Light: | ultrasonic metal thickness gauge , ultrasonic thickness measuring device |
Standard Delivery
Name | Quantity |
Main body | 1 |
Probe | 1 |
Battery | 1 |
Couplant | 1 |
Carrying Case | 1 |
Operating Manual | 1 |
USB Cable | 1 |
Software | 1 |
COATING THICKNESS GAUGE
High Accuracy And Wide Range Coating Thickness Gauge With Separated Probe PG-CTG-100
Product Description:
The measuring range of this coating thickness gauge is up to 5000um. It is used for non-destructive coating thickness measurement of nonmagnetic coatings on steel and insulating coatings on non-ferrous metals. It is with separated external probe and can be replaced easily.
· High accuracy and stability, wide measuring range
· With separated probe and can be replaced easily
· 128X128 dot matrix LCD display and menu interface
· LCD shows mean, maximum, minimum and standard deviation
· User can set alarm limit and red backlight indication
· Readings can be stored, recalled and deleted
· Easy to do zero calibration and multi-point calibration supported
· Connect with PC via USB to download readings
· Multiple languages supported
· Up to 5 measurement groups supported
· Detect the type of substrates automatically
Specifications:
Model | PG-CTG-100 |
Probe | F-Probe & N-Probe |
Measuring Principle | Magnetic induction & Eddy Currents |
Measuring Range | Up to 10000 um |
Accuracy | ± (1%+5 um) |
Resolution | 0~99.9um(0.1um), others(1um) |
Calibration | One point to four points calibration, zero point calibration |
Data Group | One direct group(readings not be stored to memory) |
Four general groups (readings will be stored automatically) | |
NOTE: each group have individual statistics, alarm limit settings, and calibration | |
Statistics | No. of readings, mean, minimum, maximum and standard deviation |
Units | um, mm, mil |
Alarm | User can set the high/low alarm limit; Alarm icon displayed on LCD when over the limit |
Minimum Curvature Radius Convex | 1.5 mm |
Minimum Curvature Radius Concave | 25 mm |
Minimum Measuring Area | Diameter 6 mm |
Minimum Thickness Of Substrate | F-probe: 0.5 mm(0.02″);N-probe: 0.3 mm(0.012″) |
Computer Interface | Download data via USB |
Power Supply | Three 1.5 V AAA battery |
Operation Environment | Temperature: -10 to 50℃ |
Storage Environment | Temperature: -10 to 60°C(-4 to 158°F) |
Standard Certification | CE, ROHS, ISO 2178, 2360, GB/T 4956-2003, 4957-2003 |
Dimensions | 158mmX68mmX34mm/170g/ABS |
Standard Delivery: Main Unit,, TWO test Probes, Data Cable, Software, Coupling oil, Battery, Operation Manual, Carrying case.
Other Size and Type Available on Request.